Sunlong Medical™ Human Thrombopoietin One-Step ELISA Kit
Sunlong Medical™ Human Thrombopoietin One-Step ELISA Kit
THPO, TPO
Total $498.0
(Vip priceV)
Regular members: $398.4
  • NO.:One-EL483Hu
    Species:Human
    Assay range:31.25-2000 pg/mL
    Sensitivity:9.3 pg/mL
    Assay type:Sandwich
    Validity:2-8℃: 6 months; -20℃: 12 months
    NCBI_Gene:7066
    Sample type:Serum,Plasma
  • Goods click count:35
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories

Details

Citations

DESCRIPTION

Thrombopoietin (TPO) also known as megakaryocyte growth and development factor (MGDF), is a protein in human. The protein is a glycoprotein hormone produced by the liver and kidney, regulating the differentiation of megakaryocytes and platelets. While platelet and megakaryocyte concentrations have a negative feedback on TPO levels. It is also a humoral growth factor necessary for megakaryocyte proliferation and maturation, thrombopoiesis. TPO is the ligand for MLP/C_MPL, the product of myeloproliferative leukemia virus oncogene and one of the Class I hematopoietic cytokines. TPO promotes apoptosis of newly generated neurons in brain, an effect counteracted by Erythropoietin and neurotrophins.

PRINCIPLE OF THE ASSAY

An anti-tag antibody is pre-coated onto the bottom of wells. After adding antigen or samples, Tagged-Capture antibody and HRP-conjugated detection antibody, a sandwich complex is formed in the solution. TMB acts as a HRP substrate, and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns the solution yellow. The color intensity is proportional to the quantity of bound protein, which is measurable at 450 nm with the correction wavelength set at 630 nm.

PRECISION

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 8 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 16 separate assays to assess inter-assay precision.

Intra-assay Precision

SamplenMean (pg/mL)SDCV%
181,277.153.04.2
28241.26.72.8
38125.34.43.5

Inter-assay Precision

SamplenMean (pg/mL)SDCV%
1161,257.673.75.9
216239.86.22.6
316125.03.62.9

RECOVERY

The recovery of human Thrombopoietin spiked to three different levels throughout the range of the assay in human serum was evaluated.

Sample TypeAverage% of ExpectedRange (%)
Human serum1:210096-105
1:4113108-118

LINEARITY

To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay.

Human serum
1:2Average% of Expected100
Range (%)-
1:4Average% of Expected115
Range (%)111-120
1:8Average% of Expected109
Range (%)84-133
1:16Average% of Expected95
Range (%)76-113

CALIBRATION

This immunoassay is calibrated against a highly purified recombinant human Thrombopoietin produced at Sunlong Medical™.


Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.