Sunlong Medical™ Human Anti-Monkeypox Virus (MPXV) IgG ELISA Kit (A29L) ELISA Kit
Sunlong Medical™ Human Anti-Monkeypox Virus (MPXV) IgG ELISA Kit (A29L) ELISA Kit
Human Anti-Monkeypox Virus (MPXV) IgG ELISA Kit (A29L), drug concentration, pharmacokinetic
Total $617.0
(Vip priceV)
Regular members: $493.6
  • NO.:ADA0281
    Assay range:0.07 - 50 ng/mL
    Sensitivity:0.05 ng/mL
    Assay type:Sandwich
    Validity:2-8℃: 6 months
    Sample type:Serum, Plasma
  • Goods click count:0
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories
View History [Clear]

Details

Citations

DESCRIPTION

Used for the quantitative determination of Human Anti-Monkeypox virus IgG (A29L) concentration in serum and plasma.

PRINCIPLE OF THE ASSAY

This assay employs the quantitative competitive enzyme immunoassay technique. Recombinant Monkeypox virus A29L antigen has been pre-coated onto a microplate. Standards or samples are premixed with biotin-labeled antibody and then pipetted into the wells. Human Anti-Monkeypox virus IgG (A29L) in the sample competitively binds to the pre-coated protein with biotin-labeled Human Anti-Monkeypox virus IgG (A29L). After washing away any unbound substances, Streptavidin-HRP is added to the wells. Following a wash to remove any unbound enzyme reagent, a substrate solution is added to the wells and color develops in inversely proportion to the amount of Human Anti-Monkeypox virus IgG (A29L) bound in the initial step. The color development is stopped and the intensity of the color is measured.

PRECISION

Intra-Assay Precision (Precision within an assay): <20% Three samples of known concentration were tested sixteen times on one plate to assess intra-assay precision. Inter-Assay Precision (Precision between assays): <20% Three samples of known concentration were tested in twenty four separate assays to assess inter-assay precision.

Sample 1 2 3 1 2 3
n 16 16 16 24 24 24
Mean (ng/mL) 16282.8 4176.8 1072.5 16037.3 4253.0 1036.4
Standard deviation 1668.9 471.1 143.4 1661.9 466.5 213.8
CV \(%\) 10.2 11.3 13.4 10.4 11.0 20.6

RECOVERY

The recovery of Human Anti-Monkeypox virus IgG (A29L) spiked to three different levels in human serum samples throughout the range of the assay was evaluated.

Sample Dilution factor Average (%) Range (%)
Human serum (n=4) 1:10 97 76-121
1:20 96 78-115

LINEARITY

To assess the linearity of the assay, human serum samples were spiked with high concentrations of Human Anti-Monkeypox virus IgG (A29L) and diluted with the Standard Diluent to produce samples with values within the dynamic range of the assay.

Sample Dilution factor Average (%) Range (%)
Human serum (n=4) 1:2 100 94-112
1:4 92 86-96
1:8 86 85-87
1:16 92 89-94

Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.