DESCRIPTION
Angiotensinogen(AGT), a precursor of angiotensin II (Ang II), is expressed and synthesized largely in the liver and cleaved by the enzyme renin in response to lowered blood pressure. It has a key role in mediating vascular constriction and regulating salt and fluid homeostasis. The resulting product, angiotensin I, is then cleaved by angiotensin converting enzyme (ACE) to generate the physiologically active enzyme angiotensin II. Mutations in this gene are associated with susceptibility to essential hypertension, and can cause renal tubular dysgenesis, a severe disorder of renal tubular development.
PRINCIPLE OF THE ASSAY
An anti-tag antibody is pre-coated onto the bottom of wells. After adding antigen or samples, Tagged-Capture antibody and HRP-conjugated detection antibody, a sandwich complex is formed in the solution. TMB acts as a HRP substrate, and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns the solution yellow. The color intensity is proportional to the quantity of bound protein, which is measurable at 450 nm with the correction wavelength set at 630 nm.
PRECISION
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 8 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 16 separate assays to assess inter-assay precision.
Intra-assay Precision
Sample n Mean (ng/mL) SD CV% 1 8 5.42 0.13 2.40 2 8 1.27 0.04 3.15 3 8 0.66 0.02 3.03 Inter-assay Precision
Sample n Mean (ng/mL) SD CV% 1 16 5.46 0.11 2.01 2 16 1.27 0.03 2.36 3 16 0.66 0.02 3.03 RECOVERY
The recovery of human Angiotensinogen/AGT spiked to three different levels throughout the range of the assay in various matrices was evaluated.
Sample Type Average% of Expected Range (%) Human serum 1:6,400 116 112-120 1:12,800 109 107-112 Urine 1:8 119 107-127 LINEARITY
To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. (The human serum was initially diluted 1:800.)
Human serum Urine 1:2 Average% of Expected 100 100 Range (%) - - 1:4 Average% of Expected 90 101 Range (%) 88-91 94-107 1:8 Average% of Expected 83 99 Range (%) 79-88 88-110 1:16 Average% of Expected 92 97 Range (%) 88-97 84-110 CALIBRATION
This immunoassay is calibrated against a highly purified recombinant human Human Angiotensinogen/AGT One-Step ELISA Kit produced at Sunlong Medical™.
Ordering & shipping
- Minimum order: 1 kit
- Lead time: varies with order quantity and specifications. Please consult your local distributor or our sales team for confirmation
- Payment: T/T 100% in advance; PayPal; Alibaba Trade Assurance
- Shipping: FedEx / DHL / UPS express; cold-chain packing available on request
- Price: USD, per kit (48T / 96T options available)
+86 571 56623320
[email protected]
SUNLONG BIOTECH

Scan Wechat Qrcode