TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human CD164 One-Step ELISA Kit
Sunlong Medical™ Human CD164 One-Step ELISA Kit
MGC-24, MGC-24v, MUC-24, Multi-glycosylated core protein 24
Total $498.0
(Vip priceV)
Regular members: $398.4
  • NO.:One-EL046Hu
    Species:Human
    Assay range:78.1-5000 pg/mL
    Sensitivity:23.2 pg/mL
    Assay type:Sandwich
    Validity:2-8℃: 6 months; -20℃: 12 months
    NCBI_Gene:8763
    Sample type:Serum, Plasma, Cell lysate
  • Goods click count:26
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories

Details

Citations

DESCRIPTION

Sialomucins are a heterogeneous group of secreted or membrane-associated mucins that appear to play two key but opposing roles in vivo: first as cytoprotective or antiadhesive agents, and second as adhesion receptors. CD164 is a type I integral transmembrane sialomucin that functions as an adhesion receptor. It is known to function as a receptor that regulates stem cell localization to the bone marrow. Important role of CD164 in prostate cancer metastasis, promoting myogenesis and regulating myoblast migration so far been revealed.

PRINCIPLE OF THE ASSAY

An anti-tag antibody is pre-coated onto the bottom of wells. After adding antigen or samples, Tagged-Capture antibody and HRP-conjugated detection antibody, a sandwich complex is formed in the solution. TMB acts as a HRP substrate, and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns the solution yellow. The color intensity is proportional to the quantity of bound protein, which is measurable at 450 nm with the correction wavelength set at 630 nm.

PRECISION

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 8 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 16 separate assays to assess inter-assay precision.

Intra-assay Precision

SamplenMean (pg/mL)SDCV%
182,590.461.12.4
28644.29.51.5
38318.410.13.2

Inter-assay Precision

SamplenMean (pg/mL)SDCV%
1162,636.272.42.7
216646.313.32.1
316316.613.24.2

RECOVERY

The recovery of human CD164 spiked to three different levels throughout the range of the assay in various matrices was evaluated.

Sample TypeAverage% of ExpectedRange (%)
Human plasma1:168276-88
Cell lysate1:2569585-108

LINEARITY

To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. (The cell lysate was initially diluted 1:64.)

Human plasmaCell lysate
1:2Average% of Expected100100
Range (%)--
1:4Average% of Expected12589
Range (%)120-13185-94
1:8Average% of Expected12479
Range (%)123-12570-88
1:16Average% of Expected9280
Range (%)91-9479-82

CALIBRATION

This immunoassay is calibrated against a highly purified recombinant human CD164 produced at Sunlong Medical™.


Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.