TEL: +86 571 56623320 EMAIL: [email protected]
DESCRIPTION
Myocyte-specific enhancer factor 2D (MEF2D) is a transcription factor belonging to the MEF2 family, which plays critical roles in regulating gene expression during muscle development, neuronal differentiation, and immune cell function. MEF2D binds to specific DNA sequences in the promoter regions of target genes and interacts with various cofactors, including histone deacetylases and myogenic regulatory factors, to modulate transcriptional activity. Dysregulation of MEF2D has been implicated in several pathological conditions, including cancer, where it functions as either an oncogene or tumor suppressor depending on cellular context. In B-cell acute lymphoblastic leukemia (B-ALL), chromosomal translocations involving MEF2D lead to fusion proteins that drive leukemogenesis. Additionally, MEF2D contributes to neurodegenerative diseases through its role in neuronal survival and apoptosis.
PRINCIPLE OF THE ASSAY
Sandwich ELISA structure (Detection antibody labeled with HRP) A capture antibody is pre-coated onto the bottom of wells which binds to analyte of interest. A detection antibody labeled with HRP also binds to the analyte. TMB acts as the HRP substrate and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns solution yellow. The color intensity is proportional to the quantity of bound protein which is measurable at 450 nm with the correction wavelength set at 630 nm.
PRECISION
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 8 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 16 separate assays to assess inter-assay precision.
Intra-assay Precision
Sample n Mean (ng/mL) SD CV% 1 8 4.87 0.26 5.34 2 8 1.44 0.07 4.86 3 8 0.77 0.04 5.19 Inter-assay Precision
Sample n Mean (ng/mL) SD CV% 1 16 4.92 0.23 4.67 2 16 1.41 0.10 7.09 3 16 0.81 0.05 6.17 RECOVERY
The recovery of human MEF2D spiked to three different levels throughout the range of the assay in cell lysate was evaluated.
Sample Type Average% of Expected Range (%) Cell lysate 1:160 98 94-101 LINEARITY
To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. (The cell lysate was initially diluted 1:10.)
Cell lysate 1:2 Average% of Expected 100 Range (%) - 1:4 Average% of Expected 109 Range (%) 108-110 1:8 Average% of Expected 114 Range (%) 113-116 1:16 Average% of Expected 119 Range (%) 116-122 CALIBRATION
This immunoassay is calibrated against a highly purified recombinant human Human MEF2D Sandwich ELISA Kit produced at Sunlong Medical™.
Ordering & shipping
- Minimum order: 1 kit
- Lead time: varies with order quantity and specifications. Please consult your local distributor or our sales team for confirmation
- Payment: T/T 100% in advance; PayPal; Alibaba Trade Assurance
- Shipping: FedEx / DHL / UPS express; cold-chain packing available on request
- Price: USD, per kit (48T / 96T options available)
+86 571 56623320
[email protected]
SUNLONG BIOTECH

Scan Wechat Qrcode