Sunlong Medical™ Human COMP ELISA Kit
Sunlong Medical™ Human COMP ELISA Kit
COMP, EDM1, EPD1, MED, PSACH, THBS5, Thrombospondin 5, TSP5
Total $468.0
(Vip priceV)
Regular members: $374.4
  • NO.:EL0544Hu
    Species:Human
    Assay range:31.25 - 2000 pg/mL
    Sensitivity:1.1 pg/mL
    Assay type:Sandwich
    Validity:2-8℃: 6 months; -20℃: 12 months
    NCBI_Gene:1311
    Sample type:Serum, Plasma, Cell culture supernatants
  • Goods click count:19
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories

Details

Citations

DESCRIPTION

COMP is a secreted pentameric glycoprotein built from modular units and belongs to the thrombospondin protein family. COMP is expressed by hypertrophic chondrocytes and osteoblasts during endochondral ossification, and its expression is increased during fracture healing. COMP is involved in the assembly of collagen fibrils and other structural matrix components. COMP interacts with a number of cartilage ECM proteins, including fibronectin, collagen I, II IX, XII, and XIV, matrilins, as well as proteoglycans such as aggrecan and others.

PRINCIPLE OF THE ASSAY

Sandwich ELISA structure (Detection antibody labeled with biotin) A capture antibody is pre-coated onto the bottom of wells which binds to analyte of interest. A detection antibody labeled with biotin also binds to the analyte. Streptavidin-HRP binds to the biotin. TMB acts as the HRP substrate and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns solution yellow. The color intensity is proportional to the quantity of bound protein which is measurable at 450 nm with the correction wavelength set at 630 nm.

PRECISION

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 20 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 24 separate assays to assess inter-assay precision.

Intra-assay Precision

SamplenMean (pg/mL)SDCV%
120818.170.18.6
220194.218.39.4
32051.54.69.0

Inter-assay Precision

SamplenMean (pg/mL)SDCV%
124874.381.09.3
224206.020.59.9
32444.24.49.9

RECOVERY

The recovery of human COMP spiked to three different levels throughout the range of the assay in various matrices was evaluated.

Sample TypeAverage% of ExpectedRange (%)
Human serum1:16010076-127
1:32010787-121
Cell culture supernatant1:210573-122
1:4110101-122

LINEARITY

To assess the linearity of the assay, cell culture supernatant was spiked with high concentrations of human COMP in various matrices and diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. Serum was diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay.(The serum samples were initially diluted 1:80)

Human serumCell culture supernatant
1:2Average% of Expected100117
Range (%)-115-119
1:4Average% of Expected92121
Range (%)83-104111-130
1:8Average% of Expected9498
Range (%)84-10697-100
1:16Average% of Expected9486
Range (%)88-10785-88

CALIBRATION

This immunoassay is calibrated against a highly purified recombinant human COMP produced at Sunlong Medical™.


Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.