Assay Principle
This kit employs double antibody sandwich ELISA technology: Capture Antibody is coated on the microplate to capture IL-6 from samples and standards. After washing, biotin-labeled Detection Antibody is added and incubated, followed by washing to form a "Capture Antibody-Antigen-Detection Antibody" immune-complex. Subsequently, Streptavidin-Horseradish Peroxidase (SA-HRP) is added and incubated. After incubation and washing, TMB Substrate is added for color development. If the target analyte is present in the sample, a blue color develops. Stop Solution is then added to terminate the reaction. During the assay, unbound components are washed away. The Optical Density (OD) is measured at 450 nm using a microplate reader. The intensity of the color is proportional to the IL-6 concentration in the sample, and the concentration is calculated by plotting a standard curve.
Gene ID: 3569
Antigen Sequence:full-length gene sequence
Q75MH2_HUMAN:MNSFSTSAFGPVAFSLGLLLVLPAAFPAPVPPGEDSKDVAAPHRQPLTSSERIDKQIRYILDGISALRKETCNKSNMCESSKEALAE
NNLNLPKMAEKDGCFQSGFNEETCLVKIITGLLEFEVYLEYLQNRFESSEEQARAVQMSTKVLIQFLQKKAKNLDAITTPDPTTNASLLTKLQAQNQWLQ
DMTTHLILRSFKEFLQSSLRALRQM
Typical Data
The following data and curve are for reference only. The experimenter must establish a standard curve based on their own experimental data.
Standard Conc. (pg/mL)
2000
1000
500
250
125
62.5
31.25
0
OD Value
2.709
1.533
0.792
0.423
0.223
0.132
0.087
0.036
Corrected OD Value
2.673
1.497
0.756
0.387
0.187
0.096
0.051
0