Product overview
Antibody Stripping Buffer (For mIHC Fluorescence Kit) (Catalog No. SLAR0002) is used in TSA-based multiplex immunofluorescence to remove the antibody of the previous round, so that several targets can be stained sequentially on one slide while the covalently bound TSA fluorophore stays in place. It is recommended for frozen sections, cell smears, cell climbing slices and fragile tissues; for paraffin sections, EDTA or citrate heat retrieval is preferred.
Specifications
Item Description Catalog No. SLAR0002 Product name Antibody Stripping Buffer (For mIHC Fluorescence Kit) Format Liquid, ready to use after warming to 37℃ Size 30 mL Storage Room temperature (RT); stable for 12 months Sample type Frozen sections, cell smears, cell climbing slices, fragile tissue Intended use For research use only How to use
- Warm the buffer: Warm the buffer to 37℃ until it is completely dissolved and free of precipitate before each use.
- Apply to the section: After the TSA fluorescence staining step and PBS washes (3 × 5 min), apply an appropriate volume of pre-warmed buffer to cover the tissue.
- Incubate: Incubate for 5-20 min at 37℃, then discard the buffer.
- Repeat: Apply fresh buffer once more to cover the tissue and incubate for another 5-20 min at 37℃, then discard.
- Wash: Wash the slide with PBS (pH 7.4) for 5 min, repeated 3 times, and continue with the next round of primary antibody incubation.
Notes
- Stripping efficiency depends on section thickness, stripping temperature and time, and the primary antibody used; adjust the incubation time accordingly.
- If stripping is incomplete, lower the primary antibody concentration or move that antibody to the last round.
- The buffer flows off the section easily; replenish it promptly if it runs off.
- Make sure the reagent is completely dissolved before use; if precipitate is present, warm at 37℃ until clear.
- Preferentially use this buffer for cell smears, cell climbing slices, frozen sections and fragile bone tissue; for paraffin sections, EDTA or citrate heat retrieval is preferred.
- The buffer is slightly acidic; over-stripping (too long or too hot) can reduce antigen recognition and weaken DAPI nuclear staining.
- Do not use this buffer on unfixed sections.
For research use only
This product is for research use only and is not intended for diagnostic procedures.
Ordering & shipping
- Order by catalog number SLAR0002; size 30 mL.
- Quotation and bulk pricing: [email protected].
- Shipped at room temperature; store at RT upon arrival.
- Batch-specific documents are available on request.
- Technical support for multiplex panel design is available from our application team.