  • NO.:ADA0184
    Assay range:125 - 8,000 ng/mL
    Sensitivity:29.40 ng/mL
    Assay type:Competitive
    Validity:2-8℃: 6 months
    Sample type:Serum, Plasma
  • Goods click count:0
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories

Details

Citations

DESCRIPTION

Used for the quantitative determination of Anti-Nivolumab concentration in serum and plasma.

PRINCIPLE OF THE ASSAY

This assay employs the quantitative sandwich enzyme immunoassay technique. Nivolumab has been pre-coated onto a microplate. Samples or standards are pipetted into microwells and Anti-Nivolumab will be captured by immobilized Nivolumab. After washing away any unbound substances, a biotin-labeled Nivolumab is added to the wells. After washing away any unbound substances, Streptavidin-HRP is added to the wells. Following a wash to remove any unbound enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of Anti-Nivolumab bound in the initial step. The color development is stopped and the intensity of the color is measured.

PRECISION

Intra-Assay Precision (Precision within an assay): <10% Three samples of known concentration were tested sixteen times on one plate to assess intra-assay precision. Inter-Assay Precision (Precision between assays): <15% Three samples of known concentration were tested in twenty four separate assays to assess inter-assay precision.

Sample 1 2 3 1 2 3
n 16 16 16 24 24 24
Mean (ng/mL) 101.1 25.5 6.8 110.2 27.1 7.6
Standard deviation 3.8 0.8 0.6 4.0 1.3 0.5
CV \(%\) 3.7 3.3 8.1 3.6 4.6 6.7

RECOVERY

The recovery of Anti-Nivolumab spiked to three different levels in human serum samples throughout the range of the assay was evaluated.

Sample Dilution factor Average (%) Range (%)
Human serum (n=3) 1:10 92 81-111
1:20 87 80-92

LINEARITY

To assess the linearity of the assay, human serum samples were spiked with high concentrations of Anti-Nivolumab and diluted with the Standard Diluent to produce samples with values within the dynamic range of the assay.

Sample Dilution factor Average (%) Range (%)
Human serum (n=3) 1:2 105 104-107
1:4 113 108-120
1:8 110 107-112
1:16 110 97-120

Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.