TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Necitumumab ELISA Kit
Sunlong Medical™ Necitumumab ELISA Kit
Necitumumab, drug concentration, pharmacokinetic
Total $1128.0
(Vip priceV)
Regular members: $902.4
  • NO.:ADA0019
    Assay range:0.31 - 5 μg/mL
    Sensitivity:0.156 μg/ml
    Validity:2-8℃: 6 months
    Sample type:Serum, Plasma
  • Goods click count:0
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories

Details

Citations

DESCRIPTION

Used for the quantitative determination of Necitumumab concentration in serum and plasma.

PRINCIPLE OF THE ASSAY

This assay employs the quantitative competitive enzyme immunoassay technique. Recombinant Human EGFR has been pre-coated onto a microplate. Standards or samples are premixed with biotin-labeled antibody and then pipetted into the wells. Necitumumab in the sample competitively binds to the pre-coated protein with biotin-labeled Necitumumab. After washing away any unbound substances, Streptavidin-HRP is added to the wells. Following a wash to remove any unbound enzyme reagent, a substrate solution is added to the wells and color develops in inversely proportion to the amount of Necitumumab bound in the initial step. The color development is stopped and the intensity of the color is measured.

PRECISION

Intra-Assay Precision (Precision within an assay): <20% Three samples of known concentration were tested sixteen times on one plate to assess intra-assay precision. Inter-Assay Precision (Precision between assays): <20% Three samples of known concentration were tested in twenty four separate assays to assess inter-assay precision.

Sample 1 2 3 1 2 3
n 16 16 16 24 24 24
Mean (ng/mL) 392.4 71.0 24.2 231.4 65.8 23.4
Standard deviation 61.0 9.5 3.6 44.5 11.9 4.5
CV \(%\) 15.5 13.4 15.1 19.2 18.1 19.2

RECOVERY

The recovery of Necitumumab spiked to three different levels in human serum samples throughout the range of the assay was evaluated.

Sample Dilution factor Average (%) Range (%)
Human serum (n=4) 1:10 93 80-116
1:20 93 83-105

LINEARITY

To assess the linearity of the assay, human serum samples were spiked with high concentrations of Necitumumab and diluted with the Standard Diluent to produce samples with values within the dynamic range of the assay.

Sample Dilution factor Average (%) Range (%)
Human serum (n=3) 1:2 90 80-110
1:4 90 83-96
1:8 92 90-94
1:16 96 85-112

Ordering & shipping

  • Minimum order: 1 kit
  • Lead time: varies with order quantity and specifications. Please consult your local distributor or our sales team for confirmation
  • Payment: T/T 100% in advance; PayPal; Alibaba Trade Assurance
  • Shipping: FedEx / DHL / UPS express; cold-chain packing available on request
  • Price: USD, per kit (48T / 96T options available)

Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.