TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human uPA/Urokinase One-Step ELISA Kit
Sunlong Medical™ Human uPA/Urokinase One-Step ELISA Kit
PLAU, UPA, ATF, EC:3.4.21.73, u PA
Total $498.0
(Vip priceV)
Regular members: $398.4
  • NO.:One-EL507Hu
    Species:Human
    Assay range:31.25-2000 pg/mL
    Sensitivity:1.5 pg/mL
    Assay type:Sandwich
    Validity:2-8℃: 6 months; -20℃: 12 months
    NCBI_Gene:5328
    Sample type:Serum,Plasma,Cell culture supernatants,Urine,Cell lysates
  • Goods click count:46
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories
View History [Clear]

Details

Citations

DESCRIPTION

PLAU(Urokinase-type plasminogen activator) is also named as uPA and belongs to the peptidase S1 family. uPA initiates a proteolytic cascade, which degrades extracellular matrix during tissue growth and remodelling. The secreted proform of uPA is activated after binding to a specific high affinity cell surface receptor. Secreted uPA is exposed to rapid inactivation in the pericellular space by plasminogen activator inhibitor-1 (PAI-1), which is stored in the extracellular matrix bound to vitronectin. It has 2 isoforms produced by alternative splicing. Defects in PLAU are the cause of Quebec platelet disorder (QPD).

PRINCIPLE OF THE ASSAY

An anti-tag antibody is pre-coated onto the bottom of wells. After adding antigen or samples, Tagged-Capture antibody and HRP-conjugated detection antibody, a sandwich complex is formed in the solution. TMB acts as a HRP substrate, and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns the solution yellow. The color intensity is proportional to the quantity of bound protein, which is measurable at 450 nm with the correction wavelength set at 630 nm.

PRECISION

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 8 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 16 separate assays to assess inter-assay precision.

Intra-assay Precision

SamplenMean (pg/mL)SDCV%
181,090.955.65.1
28268.710.74.0
38133.45.13.8

Inter-assay Precision

SamplenMean (pg/mL)SDCV%
1161,080.044.04.1
216266.58.23.1
316133.34.13.1

RECOVERY

The recovery of human uPA/Urokinase spiked to three different levels throughout the range of the assay in various matrices was evaluated.

Sample TypeAverage% of ExpectedRange (%)
Human serum1:49789-104
Cell culture supernatant1:4108104-114
1:8115109-120
Urine1:32011499-127
1:640110103-120
Cell lysate1:3208280-85
1:6409792-103

LINEARITY

To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. (The urine and cell lysate was initially diluted 1:40.)

Human serumCell culturesupernatantUrineCell lysate
1:2Average% of Expected100100100100
Range (%)----
1:4Average% of Expected1129410098
Range (%)106-11983-10499-10192-104
1:8Average% of Expected1099896115
Range (%)101-11797-10095-97114-115
1:16Average% of Expected1158097124
Range (%)113-11777-8396-98119-129

CALIBRATION

This immunoassay is calibrated against a highly purified recombinant human Human uPA/Urokinase One-Step ELISA Kit produced at Sunlong Medical™.


Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.