Sunlong Medical™ Human Filamin A One-Step ELISA Kit
Sunlong Medical™ Human Filamin A One-Step ELISA Kit
FLNA, ABP-280, Actin-binding protein 280, Alpha filamin, Alpha-filamin
Total $498.0
(Vip priceV)
Regular members: $398.4
  • NO.:One-EL492Hu
    Species:Human
    Assay range:78.1-5000 pg/mL
    Sensitivity:26.9 pg/mL
    Assay type:Sandwich
    Validity:2-8℃: 6 months; -20℃: 12 months
    NCBI_Gene:2316
    Sample type:Serum,Plasma,Cell lysates
  • Goods click count:49
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories

Details

Citations

DESCRIPTION

FLNA encodes a 280 kDa widely expressed actin binding protein called filamin A which can crosslinks actin filaments and links actin filaments to membrane glycoproteins to form a three-dimensional network. And filamin A could interact with many other proteins, involved in receptor activation, cell migration and adhesion, cell proliferation, inflammation and tumorigenesis, studies have been reported that Filamin A overexpressed in multiple types of tumors, suggesting Filamin A may involved in cancer aggressiveness. What's more, Filamin A is an causative gene of periventricular nodular heterotopia (PNH).

PRINCIPLE OF THE ASSAY

An anti-tag antibody is pre-coated onto the bottom of wells. After adding antigen or samples, Tagged-Capture antibody and HRP-conjugated detection antibody, a sandwich complex is formed in the solution. TMB acts as a HRP substrate, and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns the solution yellow. The color intensity is proportional to the quantity of bound protein, which is measurable at 450 nm with the correction wavelength set at 630 nm.

PRECISION

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 8 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 16 separate assays to assess inter-assay precision.

Intra-assay Precision

SamplenMean (pg/mL)SDCV%
182,610.455.82.1
28628.210.81.7
38326.88.22.5

Inter-assay Precision

SamplenMean (pg/mL)SDCV%
1162,614.846.71.8
216631.69.31.5
316334.019.65.9

RECOVERY

The recovery of human Filamin A spiked to three different levels throughout the range of the assay in various matrices was evaluated.

Sample TypeAverage% of ExpectedRange (%)
Human serum1:20010894-122
1:400104102-105
Cell lysate1:508885-90
1:1009388-101

LINEARITY

To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. (The human serum was initially diluted 1:25. The cell lysate was initially diluted 1:100.)

Human serumCell lysate
1:2Average% of Expected100100
Range (%)--
1:4Average% of Expected8996
Range (%)87-9082-109
1:8Average% of Expected9397
Range (%)86-10080-114
1:16Average% of Expected88100
Range (%)83-9381-119

CALIBRATION

This immunoassay is calibrated against a highly purified recombinant human Filamin A produced at Sunlong Medical™.


Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.