TEL: +86 571 56623320    EMAIL: [email protected]

Sunlong Medical™ Human Fibrinogen Alpha Chain One-Step ELISA Kit
Sunlong Medical™ Human Fibrinogen Alpha Chain One-Step ELISA Kit
FGA, Fib2, Fibrinopeptide A
Total $498.0
(Vip priceV)
Regular members: $398.4
  • NO.:One-EL490Hu
    Species:Human
    Assay range:46.88-3000 pg/mL
    Sensitivity:3.2 pg/mL
    Assay type:Sandwich
    Validity:2-8℃: 6 months; -20℃: 12 months
    NCBI_Gene:2243
    Sample type:Serum,Plasma,Urine
  • Goods click count:57
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories

Details

Citations

DESCRIPTION

Fibrinogen is a soluble plasma glycoprotein synthesized in the liver. It is composed of two sets of three structurally different subunits: alpha (FGA), beta (FGB), gamma (FGG). Fibrinogen is converted by thrombin into fibrin during blood coagulation. Fibrinogen and fibrin play overlapping roles in blood clotting, fibrinolysis, cellular and matrix interactions, the inflammatory response, wound healing, and neoplasia. FGA is the alpha chain of fibrinogen. During conversion of fibrinogen to fibrin, fibrinopeptide A is cleaved from FGA by thrombin.

PRINCIPLE OF THE ASSAY

An anti-tag antibody is pre-coated onto the bottom of wells. After adding antigen or samples, Tagged-Capture antibody and HRP-conjugated detection antibody, a sandwich complex is formed in the solution. TMB acts as a HRP substrate, and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns the solution yellow. The color intensity is proportional to the quantity of bound protein, which is measurable at 450 nm with the correction wavelength set at 630 nm.

PRECISION

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 8 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 16 separate assays to assess inter-assay precision.

Intra-assay Precision

SamplenMean (pg/mL)SDCV%
181,634.044.52.7
28362.27.22.0
38181.87.24.0

Inter-assay Precision

SamplenMean (pg/mL)SDCV%
1161,637.755.03.4
216363.07.62.1
316181.86.63.6

RECOVERY

The recovery of human Fibrinogen Alpha Chain spiked to three different levels throughout the range of the assay in in various matrices was evaluated.

Sample TypeAverage% of ExpectedRange (%)
Human serum1:6,4009896-101
1:12,8009996-104
Urine1:1,2809995-103
1:2,56010096-107

LINEARITY

To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. (The human serum was initially diluted 1:800. The urine was initially diluted 1:160.)

Human serumUrine
1:2Average% of Expected100100
Range (%)--
1:4Average% of Expected9496
Range (%)93-9494-99
1:8Average% of Expected9298
Range (%)91-9482-113
1:16Average% of Expected9091
Range (%)87-9383-98

CALIBRATION

This immunoassay is calibrated against a highly purified recombinant human Fibrinogen Alpha Chain produced at Sunlong Medical™.


Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.