Sunlong Medical™ Human CCL27 One-Step ELISA Kit
Sunlong Medical™ Human CCL27 One-Step ELISA Kit
C C motif chemokine 27, CC chemokine ILC, C-C motif chemokine 27, CCL 27, CCL-27
Total $498.0
(Vip priceV)
Regular members: $398.4
  • NO.:One-EL036Hu
    Species:Human
    Assay range:23.4-1500 pg/mL
    Sensitivity:6.4 pg/mL
    Assay type:Sandwich
    Validity:2-8℃: 6 months; -20℃: 12 months
    NCBI_Gene:10850
    Sample type:Serum, Plasma
  • Goods click count:42
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories

Details

Citations

DESCRIPTION

CCL27, also known as CTACK, is a member of the CC chemokine subfamily. CCL27 is predominantly expressed in skin and selectively attracts cutaneous lymphocyte antigen-positive T cells and Langerhans cells. The CCL27 secreted from keratinocytes was reportedly involved in inflammatory skin diseases such as atopic dermatitis, contact dermatitis, and psoriasis. CCL27 is a ligand to CCR10. The binding of CCL27 to CCR10 on T cells promotes their migration to the skin, where they can then participate in local immune responses.

PRINCIPLE OF THE ASSAY

An anti-tag antibody is pre-coated onto the bottom of wells. After adding antigen or samples, Tagged-Capture antibody and HRP-conjugated detection antibody, a sandwich complex is formed in the solution. TMB acts as a HRP substrate, and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns the solution yellow. The color intensity is proportional to the quantity of bound protein, which is measurable at 450 nm with the correction wavelength set at 630 nm.

PRECISION

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 8 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 16 separate assays to assess inter-assay precision.

Intra-assay Precision

SamplenMean (pg/mL)SDCV%
18757.914.82.0
28179.12.01.1
3889.62.83.1

Inter-assay Precision

SamplenMean (pg/mL)SDCV%
116772.018.92.4
216182.24.12.3
31690.12.62.9

RECOVERY

The recovery of human CCL27 spiked to three different levels throughout the range of the assay in human plasma was evaluated.

Sample TypeAverage% of ExpectedRange (%)
Human plasma1:8118115-123
1:16116115-118

LINEARITY

To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay.

Human plasma
1:2Average% of Expected100
Range (%)-
1:4Average% of Expected119
Range (%)116-121
1:8Average% of Expected121
Range (%)120-122
1:16Average% of Expected121
Range (%)117-125

CALIBRATION

This immunoassay is calibrated against a highly purified recombinant human CCL27 produced at Sunlong Medical™.


Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.