Sunlong Medical™ Mouse CCL11/Eotaxin ELISA Kit
Sunlong Medical™ Mouse CCL11/Eotaxin ELISA Kit
Ccl11, eotaxin, Scya11
Total $468.0
(Vip priceV)
Regular members: $374.4
  • NO.:EL1272Mo
    Species:Mouse
    Assay range:7.8-500 pg/mL
    Sensitivity:2.9 pg/mL
    Assay type:Sandwich
    Validity:2-8℃: 6 months; -20℃: 12 months
    NCBI_Gene:20292
    Sample type:Serum, Plasma, Cell culture supernatants
  • Goods click count:25
  • Product Spec:
  • Quantity: - +
  • Limit points for buying:0 Points
  • Manual
  • Add to cart Inquiry Add to favorite
All categories

Details

Citations

DESCRIPTION

CCL11 also named Eotaxin, was initially discovered as an eosinophil-specific chemoattractant. CCL11 plays a central role in both allergic and non-allergic inflammatory reactions by recruiting immune cells such as eosinophils, basophils and Th2 lymphocytes. CCL11 binds to the chemokine receptors CCR2, CCR3 and CCR5, with highest affinity to CCR3. High levels of CCL11 have been described in several chronic inflammatory diseases, such as allergic rhinitis, atopic dermatitis, asthma, gastrointestinal disease and rheumatoid arthritis.

PRINCIPLE OF THE ASSAY

Sandwich ELISA structure (Detection antibody labeled with biotin) A capture antibody is pre-coated onto the bottom of wells which binds to analyte of interest. A detection antibody labeled with biotin also binds to the analyte. Streptavidin-HRP binds to the biotin. TMB acts as the HRP substrate and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns solution yellow. The color intensity is proportional to the quantity of bound protein which is measurable at 450 nm with the correction wavelength set at 630 nm.

PRECISION

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 20 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 24 separate assays to assess inter-assay precision.

Intra-assay Precision

SamplenMean (pg/mL)SDCV%
120226.214.36.3
22057.52.74.6
32013.80.64.6

Inter-assay Precision

SamplenMean (pg/mL)SDCV%
124242.121.08.7
22457.52.85.0
32415.40.53.1

RECOVERY

The recovery of mouse CCL11/Eotaxin spiked to three different levels throughout the range of the assay in various matrices was evaluated.

Sample TypeAverage% of ExpectedRange (%)
Mouse serum1:1610092-109
1:329679-108
Cell culture supernatant1:2112103-122
1:4111103-118

LINEARITY

To assess the linearity of the assay, cell culture supernatant samples were spiked with high concentrations of mouse CCL11/Eotaxin in various matrices and diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. Mouse serum were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. (The mouse serum samples were initially diluted 1:2)

Mouse serumCell culture supernatant
1:2Average% of Expected100
Range (%)-
1:4Average% of Expected100106
Range (%)92-10698-115
1:8Average% of Expected11898
Range (%)116-12093-104
1:16Average% of Expected122105
Range (%)120-12494-118

CALIBRATION

This immunoassay is calibrated against a highly purified recombinant human Mouse CCL11/Eotaxin Sandwich ELISA Kit produced at Sunlong Medical™.


Partial purchase records(bought amounts latest0)

No one bought this product
Total 0 records, divided into1 pages First Prev Next Last

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha

Call us

+86 571 56623320

Address

Room 1-315, Kongle Changqing Building, No. 160 Guangye Road,Gongshu District, Hangzhou City, Zhejiang Province, China

Join Us with

Leave a message
* To protect against spam, please pass the CAPTCHA test below.
© 2005-2026 SUNLONG BIOTECH CO., LTD Copyright, All Rights Reserved.