TEL: +86 571 56623320 EMAIL: [email protected]
DESCRIPTION
RNASET2 (Ribonuclease T2) is a highly conserved enzyme in a wide range of organisms and belongs to the RNase T2 family. The main biological role of intracellular RNASET2 is to cleave or degrade exogenous or endogenous RNA substrates as well as contributing to mitochondrial RNA metabolism, and also activating immune responses. In addition, it is involved in the regulation of angiogenesis, apoptosis, cell proliferation/differentiation, and immune regulation. In cancer, dysregulated expression of RNASET2 is associated with a variety of pathological conditions, including autoimmune diseases and cancer. The calculated molecular weight of human RNASET2 is approximately 35 kDa, but due to post-translational modifications such as glycosylation, its actual molecular weight may be observed as a mildly glycosylated form with a molecular weight of 38-45 kDa and a highly glycosylated form with a molecular weight of 50-80 kDa.
PRINCIPLE OF THE ASSAY
Sandwich ELISA structure (Detection antibody labeled with HRP) A capture antibody is pre-coated onto the bottom of wells which binds to analyte of interest. A detection antibody labeled with HRP also binds to the analyte. TMB acts as the HRP substrate and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns solution yellow. The color intensity is proportional to the quantity of bound protein which is measurable at 450 nm with the correction wavelength set at 630 nm.
PRECISION
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 20 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 24 separate assays to assess inter-assay precision.
Intra-assay Precision
Sample n Mean (ng/mL) SD CV% 1 20 5.06 0.15 3.00 2 20 1.12 0.03 2.30 3 20 0.32 0.01 4.22 Inter-assay Precision
Sample n Mean (ng/mL) SD CV% 1 24 4.84 0.21 4.34 2 24 1.07 0.03 2.55 3 24 0.30 0.01 3.73 RECOVERY
The recovery of human RNASET2 spiked to three different levels throughout the range of the assay in human plasma was evaluated.
Sample Type Average% of Expected Range (%) Human plasma 1:8 101 76-120 LINEARITY
To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay.
Human plasma 1:2 Average% of Expected 100 Range (%) - 1:4 Average% of Expected 107 Range (%) 106-108 1:8 Average% of Expected 98 Range (%) 96-99 1:16 Average% of Expected 100 Range (%) 99-102 CALIBRATION
This immunoassay is calibrated against a highly purified recombinant human RNASET2 produced at Sunlong Medical™.
Ordering & shipping
- Minimum order: 1 kit
- Lead time: varies with order quantity and specifications. Please consult your local distributor or our sales team for confirmation
- Payment: T/T 100% in advance; PayPal; Alibaba Trade Assurance
- Shipping: FedEx / DHL / UPS express; cold-chain packing available on request
- Price: USD, per kit (48T / 96T options available)
+86 571 56623320
[email protected]
SUNLONG BIOTECH

Scan Wechat Qrcode