TEL: +86 571 56623320 EMAIL: [email protected]
DESCRIPTION
MXI1, also known as MAX Interactor 1, is a transcription factor containing a basic helix-loop-helix leucine zipper (bHLHzip) domain and belongs to the Myc-Max-Mad transcriptional network. It is a widely expressed transcriptional repressor that heterodimerizes with Max and blocks Max-Myc gene activation. MXI1 is involved in the homeostasis of differentiated organ systems and acts as a tumor suppressor in vivo. It has been implicated in several diseases, including prostate cancer and neurofibrosarcoma. In lung cancer, MXI1 expression is often low, and its poor expression is associated with poor prognosis. MXI1 is also involved in other biological processes. For example, in mesangial proliferative glomerulonephritis, MXI1 expression changes during the disease process, influencing mesangial cell proliferation. Additionally, MXI1 has been shown to be directly regulated by the HIF-1α protein in neuroblastoma and breast cancer cells.
PRINCIPLE OF THE ASSAY
Sandwich ELISA structure (Detection antibody labeled with HRP) A capture antibody is pre-coated onto the bottom of wells which binds to analyte of interest. A detection antibody labeled with HRP also binds to the analyte. TMB acts as the HRP substrate and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns solution yellow. The color intensity is proportional to the quantity of bound protein which is measurable at 450 nm with the correction wavelength set at 630 nm.
PRECISION
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 8 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 16 separate assays to assess inter-assay precision.
Intra-assay Precision
Sample n Mean (ng/mL) SD CV% 1 8 61.77 4.11 6.66 2 8 14.82 0.32 2.13 3 8 4.32 0.15 3.57 Inter-assay Precision
Sample n Mean (ng/mL) SD CV% 1 16 59.68 5.15 8.63 2 16 13.92 1.03 7.37 3 16 4.22 0.21 4.89 RECOVERY
The recovery of human MXI1 spiked to three different levels throughout the range of the assay in cell lysate was evaluated.
Sample Type Average% of Expected Range (%) Cell lysate 1:16 87 79-100 LINEARITY
To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay.
Cell lysate 1:2 Average% of Expected 100 Range (%) - 1:4 Average% of Expected 90 Range (%) 89-91 1:8 Average% of Expected 93 Range (%) 90-95 1:16 Average% of Expected 83 Range (%) 80-86 CALIBRATION
This immunoassay is calibrated against a highly purified recombinant human Human MXI1 Sandwich ELISA Kit produced at Sunlong Medical™.
Ordering & shipping
- Minimum order: 1 kit
- Lead time: varies with order quantity and specifications. Please consult your local distributor or our sales team for confirmation
- Payment: T/T 100% in advance; PayPal; Alibaba Trade Assurance
- Shipping: FedEx / DHL / UPS express; cold-chain packing available on request
- Price: USD, per kit (48T / 96T options available)
+86 571 56623320
[email protected]
SUNLONG BIOTECH