DESCRIPTION
MMP-8 (Matrix metalloproteinase-8) an enzyme that degrades fibrillar collagens imparting strength to the fetal membranes, is expressed by leukocytes and chorionic cytotrophoblast cells (PMID:15367487). The high-serum MMP-8 levels (>100 ng/mL) had poor cancer-specific survival (PMID: 29808017). MMP8 also has prognosis in patients with gastric cancer (PMID: 30192205).
PRINCIPLE OF THE ASSAY
Sandwich ELISA structure (Detection antibody labeled with HRP) A capture antibody is pre-coated onto the bottom of wells which binds to analyte of interest. A detection antibody labeled with HRP also binds to the analyte. TMB acts as the HRP substrate and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns solution yellow. The color intensity is proportional to the quantity of bound protein which is measurable at 450 nm with the correction wavelength set at 630 nm.
PRECISION
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 20 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 24 separate assays to assess inter-assay precision.
Intra-assay Precision
Sample n Mean (pg/mL) SD CV% 1 20 1,249.2 37.6 3.0 2 20 259.4 3.0 1.2 3 20 75.8 1.4 1.8 Inter-assay Precision
Sample n Mean (pg/mL) SD CV% 1 24 1,276.1 46.5 3.6 2 24 273.8 12.2 4.4 3 24 70.3 2.7 3.9 RECOVERY
The recovery of human MMP-8 spiked to three different levels throughout the range of the assay in various matrices was evaluated.
Sample Type Average% of Expected Range (%) Human plasma 1:16 83 78-90 1:32 79 76-85 Cell culture supernatant 1:32 80 72-85 1:64 81 75-85 Saliva 1:160 90 81-106 1:320 87 80-106 Tissue lysate 1:32 90 81-99 1:64 88 80-94 LINEARITY
To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. (The human plasma was initially diluted 1:4. The cell culture supernatant was initially diluted 1:2. The saliva was initially diluted 1:4. The tissue lysate was initially diluted 1:4.)
Human plasma(Sample Diluent PT1) Cell culturesupernatant (SampleDiluent PT 1) Saliva (SampleDiluent PT 1) Tissue lysate (SampleDiluent PT 3) 1:2 Average% ofExpected 100 100 100 100 Range (%) - - - - 1:4 Average% ofExpected 100 100 95 97 Range (%) 97-102 98-102 89-104 95-99 1:8 Average% ofExpected 99 105 96 102 Range (%) 89-104 101-110 87-109 95-109 1:16 Average% ofExpected 95 108 94 106 Range (%) 89-104 104-114 82-116 91-120 CALIBRATION
This immunoassay is calibrated against a highly purified recombinant human MMP-8 produced at Sunlong Medical™.
Ordering & shipping
- Minimum order: 1 kit
- Lead time: varies with order quantity and specifications. Please consult your local distributor or our sales team for confirmation