TEL: +86 571 56623320 EMAIL: [email protected]
DESCRIPTION
Thrombomodulin (THBD, also known as CD141) is an endothelial-specific type I membrane glycoprotein of 105 kDa that binds thrombin, which plays an important role as a natural anticoagulant. It is expressed mostly on the surface of vascular endothelial cells, where it probably be involved in cell differentiation or inflammation. Soluble forms of CD141 have been found in plasma and urine. It has been reported that plasma CD141 is increased in patients with diabetes mellitus, particularly those with diabetic nephropathy.
PRINCIPLE OF THE ASSAY
Sandwich ELISA structure (Detection antibody labeled with HRP) A capture antibody is pre-coated onto the bottom of wells which binds to analyte of interest. A detection antibody labeled with HRP also binds to the analyte. TMB acts as the HRP substrate and the solution color will change from colorless to blue. A stop solution containing sulfuric acid turns solution yellow. The color intensity is proportional to the quantity of bound protein which is measurable at 450 nm with the correction wavelength set at 630 nm.
PRECISION
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested 20 times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in 24 separate assays to assess inter-assay precision.
Intra-assay Precision
Sample n Mean (pg/mL) SD CV% 1 20 2,143.8 35.5 1.7 2 20 469.2 13.5 2.9 3 20 110.2 4.2 3.8 Inter-assay Precision
Sample n Mean (pg/mL) SD CV% 1 24 2,049.8 108.7 5.3 2 24 444.5 26.1 5.9 3 24 112.4 8.1 7.2 RECOVERY
The recovery of human CD141/Thrombomodulin spiked to three different levels throughout the range of the assay in various matrices was evaluated.
Sample Type Average% of Expected Range (%) Human serum 1:32 81 80-83 1:64 89 83-99 Urine 1:80 82 78-86 1:160 92 83-117 Cell lysate 1:64 88 86-90 1:128 87 78-93 LINEARITY
To assess the linearity of the assay, samples were diluted with the appropriate Sample Diluent to produce samples with values within the dynamic range of the assay. (The human serum was initially diluted 1:4. The urine was initially diluted 1:10. The cell lysate was initially diluted 1:8.)
Human serum Urine Cell lysate 1:2 Average% of Expected 100 100 100 Range (%) - - - 1:4 Average% of Expected 108 103 103 Range (%) 103-113 102-104 101-104 1:8 Average% of Expected 116 105 104 Range (%) 113-118 103-107 102-105 1:16 Average% of Expected 110 108 110 Range (%) 108-112 105-110 104-115 CALIBRATION
This immunoassay is calibrated against a highly purified recombinant human Human CD141/Thrombomodulin Sandwich ELISA Kit produced at Sunlong Medical™.
Ordering & shipping
- Minimum order: 1 kit
- Lead time: varies with order quantity and specifications. Please consult your local distributor or our sales team for confirmation
- Payment: T/T 100% in advance; PayPal; Alibaba Trade Assurance
- Shipping: FedEx / DHL / UPS express; cold-chain packing available on request
- Price: USD, per kit (48T / 96T options available)
+86 571 56623320
[email protected]
SUNLONG BIOTECH

Scan Wechat Qrcode